8.13 Zigbee and Thread - IEEE 802.15.4-2006 2.4 GHz (OQPSK DSSS1:8, 250 kbps) - RX
When measured on the CC26x2RBEM-7ID reference design with T
c
= 25 °C, V
DDS
= 3.0 V, f
RF
= 2440 MHz with
DC/DC enabled unless otherwise noted. All measurements are performed at the antenna input with a combined RX and TX
path.
All measurements are performed conducted.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
Receiver sensitivity
PER = 1%
–100
dBm
Receiver saturation
PER = 1%
> 5
dBm
Adjacent channel rejection
Wanted signal at –82 dBm, modulated interferer at
±5 MHz, PER = 1%
36
dB
Alternate channel rejection
Wanted signal at –82 dBm, modulated interferer at
±10 MHz, PER = 1%
57
dB
Channel rejection, ±15 MHz or
more
Wanted signal at –82 dBm, undesired signal is IEEE
802.15.4 modulated channel, stepped through all
channels 2405 to 2480 MHz, PER = 1%
59
dB
Blocking and desensitization,
5 MHz from upper band edge
Wanted signal at –97 dBm (3 dB above the
sensitivity level), CW jammer, PER = 1%
57
dB
Blocking and desensitization,
10 MHz from upper band edge
Wanted signal at –97 dBm (3 dB above the
sensitivity level), CW jammer, PER = 1%
63
dB
Blocking and desensitization,
20 MHz from upper band edge
Wanted signal at –97 dBm (3 dB above the
sensitivity level), CW jammer, PER = 1%
63
dB
Blocking and desensitization,
50 MHz from upper band edge
Wanted signal at –97 dBm (3 dB above the
sensitivity level), CW jammer, PER = 1%
66
dB
Blocking and desensitization,
–5 MHz from lower band edge
Wanted signal at –97 dBm (3 dB above the
sensitivity level), CW jammer, PER = 1%
60
dB
Blocking and desensitization,
–10 MHz from lower band edge
Wanted signal at –97 dBm (3 dB above the
sensitivity level), CW jammer, PER = 1%
60
dB
Blocking and desensitization,
–20 MHz from lower band edge
Wanted signal at –97 dBm (3 dB above the
sensitivity level), CW jammer, PER = 1%
63
dB
Blocking and desensitization,
–50 MHz from lower band edge
Wanted signal at –97 dBm (3 dB above the
sensitivity level), CW jammer, PER = 1%
64
dB
Spurious emissions, 30 MHz to
1000 MHz
Measurement in a 50-Ω single-ended load
–66
dBm
Spurious emissions, 1 GHz to
12.75 GHz
Measurement in a 50-Ω single-ended load
–53
dBm
Frequency error tolerance
Difference between the incoming carrier frequency
and the internally generated carrier frequency
> 350
ppm
Symbol rate error tolerance
Difference between incoming symbol rate and the
internally generated symbol rate
> 1000
ppm
RSSI dynamic range
95
dB
RSSI accuracy
±4
dB
8.14 Timing and Switching Characteristics
8.14.1 Reset Timing
PARAMETER
MIN
TYP
MAX
UNIT
RESET_N low duration
1
µs
8.14.2 Wakeup Timing
Measured over operating free-air temperature with V
DDS
= 3.0 V (unless otherwise noted). The times listed here do not
include software overhead.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
MCU, Reset to Active
850 - 4300
µs
850 - 4300
µs
SWRS232D – FEBRUARY 2019 – REVISED FEBRUARY 2021
Copyright © 2021 Texas Instruments Incorporated
19