8.4 Power Supply and Modules
over operating free-air temperature range (unless otherwise noted)
PARAMETER
MIN
TYP
MAX
UNIT
VDDS Power-on-Reset (POR) threshold
1.1 -
1.55
V
Rising threshold
1.77
V
VDDS Brown-out Detector (BOD)
External regulator mode
Rising threshold
1.64
V
VDDS Brown-out Detector (BOD), before initial boot
Rising threshold
1.70
V
Falling threshold
1.75
V
VDDS Brown-out Detector (BOD)
External regulator mode
Falling threshold
1.63
V
(1)
For boost mode (VDDR =1.95 V), TI drivers software initialization will trim VDDS BOD limits to maximum (approximately 2.0 V)
(2)
Brown-out Detector is trimmed at initial boot, value is kept until device is reset by a POR reset or the RESET_N pin
8.5 Power Consumption - Power Modes
When measured on the CC26x2RBEM-7ID reference design with T
c
= 25 °C, V
DDS
= 3.0 V with DC/DC enabled unless
otherwise noted.
PARAMETER
TEST CONDITIONS
TYP
UNIT
Core Current Consumption
I
core
Reset and Shutdown
Reset. RESET_N pin asserted or VDDS below power-on-reset
threshold
150
nA
Shutdown. No clocks running, no retention
150
Standby
without cache
retention
RTC running, CPU, 80KB RAM and (partial) register retention.
RCOSC_LF
0.94
µA
RTC running, CPU, 80KB RAM and (partial) register retention
XOSC_LF
1.09
µA
Standby
with cache retention
RTC running, CPU, 80KB RAM and (partial) register retention.
RCOSC_LF
3.2
µA
RTC running, CPU, 80KB RAM and (partial) register retention.
XOSC_LF
3.3
µA
Idle
Supply Systems and RAM powered
RCOSC_HF
675
µA
Active
MCU running CoreMark at 48 MHz
RCOSC_HF
3.39
mA
Peripheral Current Consumption
I
peri
Peripheral power
domain
Delta current with domain enabled
97.7
µA
Serial power domain Delta current with domain enabled
7.2
RF Core
Delta current with power domain enabled,
clock enabled, RF core idle
210.9
µDMA
Delta current with clock enabled, module is idle
63.9
Timers
Delta current with clock enabled, module is idle
81.0
I2C
Delta current with clock enabled, module is idle
10.1
I2S
Delta current with clock enabled, module is idle
26.3
SSI
Delta current with clock enabled, module is idle
82.9
UART
Delta current with clock enabled, module is idle
167.5
CRYPTO (AES)
Delta current with clock enabled, module is idle
25.6
PKA
Delta current with clock enabled, module is idle
84.7
TRNG
Delta current with clock enabled, module is idle
35.6
Sensor Controller Engine Consumption
SWRS232D – FEBRUARY 2019 – REVISED FEBRUARY 2021
12