eZ430-Chronos Software Projects
3.6.3.4.1.2 Access Point Based on CC1111
The
is required to program the CC1111 based RF access point. To perform the update, the
software is used to on the PC.
1. Solder a debug interface connector cable onto the CC1111 access point as shown in
.
Figure 3-16. eZ430-Chronos RF Access Point Connection to CC Debugger
CC-Debugger
RF Access Point
Pin 1
GND
Pin 2
Vcc
Pin 3
P2.2 (DC)
Pin 4
P2.1 (DD)
Pin 7
RST
Pin 9
Vcc
2. Connect RF access point to CC Debugger and press the "Reset". The LED on the CC Debugger
should become green.
3. Launch the SmartRF Programmer software
4. Open .hex file according to frequency in
C:\Program Files\Texas Instruments\eZ430-
Chronos\Recovery\RF Access Point
5. Select "Erase, program and verify"
6. Clock "Perform actions"
47
SLAU292F – November 2009 – Revised October 2013
eZ430-Chronos Software
Copyright © 2009–2013, Texas Instruments Incorporated