Data Logger PC Software
3.5.1 SimpliciTI Data Logger
The SimpliciTI Sync tab offers the possibility setting time/date of the wrist module including calibration
data besides reading out logged data.
Pairing Chronos module and PC:
1. Activate the pairing on the PC by clicking Start Access Point. When the PC is ready, the eZ430-
Chronos Data Logger status line displays
Access point started. Now start watch in acc, ppt or sync
mode.
2. Select SYnC on the eZ430-Chronos module by pushing the # button (see detailed description in
).
3. Initiate pairing on the wrist module by pushing the DOWN button to activate the selected mode. After a
short time, the link is established
Setting the Chronos module:
1. Select metric or imperial units.
2. Enter calibration data for the temperature and altitude or read back the data from the Chronos module
by clicking Read Watch.
3. Specify the data that should be logged.
4. Define logging time interval (1 to 255 seconds) in which data is stored.
5. Click Copy System Time to set the Chronos module according to read the PC's system time.
6. Click Set Watch to transfer data to the Chronos module.
7. The Chronos module shows DONE.
8. Push the DOWN button on the Chronos module to end connection
Reading out logged data:
1. Pair the wrist module with PC in case not linked yet (see the previous section,
Pairing Chronos module
and PC
)
2. Specify file name and location of log file
3. Click Download to start data transfer
4. Push the DOWN button to stop connection when the transfer has finished.
The log file is stored in CSV format. Its content appears as one line per log. Each line starts with date,
time, heart rate, temperature, and altitude. Parameters which were not logged are set to zero (according
to settings in eZ430-Chronos Data Logger PC software).
37
SLAU292F – November 2009 – Revised October 2013
eZ430-Chronos Software
Copyright © 2009–2013, Texas Instruments Incorporated