![Tews Technologies TMVE8240-11 User Manual Download Page 51](http://html1.mh-extra.com/html/tews-technologies/tmve8240-11/tmve8240-11_user-manual_1093657051.webp)
TVME8240 User Manual Issue 1.2.9
Page 51 of 70
Bit
Name
Description
8 ERR_A
Read :
0 : No Error on IP_A
1 : IP_A ERROR# Signal Asserted
Write :
No Effect
7 INT1_D
Read :
0 : No Interrupt 1 Request on IP_D
1 : Active IP_D Interrupt 1 Request
Write :
0 : No Effect
1 : Clear Edge Sensitive IP_D Interrupt 1 Status
6 INT0_D
Read :
0 : No Interrupt 0 Request on IP_D
1 : Active IP_D Interrupt 0 Request
Write :
0 : No Effect
1 : Clear Edge Sensitive IP_D Interrupt 0 Status
5 INT1_C
Read :
0 : No Interrupt 1 Request on IP_C
1 : Active IP_C Interrupt 1 Request
Write :
0 : No Effect
1 : Clear Edge Sensitive IP_C Interrupt 1 Status
4 INT0_C
Read :
0 : No Interrupt 0 Request on IP_C
1 : Active IP_C Interrupt 0 Request
Write :
0 : No Effect
1 : Clear Edge Sensitive IP_C Interrupt 0 Status
3 INT1_B
Read :
0 : No IP_B Interrupt 1 Request
1 : Active IP_B Interrupt 1 Request
Write :
0 : No Effect
1 : Clear Edge Sensitive IP_B Interrupt 1 Status
2 INT0_B
Read :
0 : No Interrupt 0 Request on IP_B
1 : Active IP_B Interrupt 0 Request
Write :
0 : No Effect
1 : Clear Edge Sensitive IP_B Interrupt 0 Status
1 INT1_A
Read :
0 : No Interrupt 1 Request on IP_A
1 : Active IP_A Interrupt 1 Request
Write :
0 : No Effect
1 : Clear Edge Sensitive IP_A Interrupt 1 Status