9
Max. starting current of heat pump
A
13.5
Required overload protections
A
16A T fuse/ 16A automatic switch, characteristic C (to be expected
during installation on power supply systems)
Internal thermal protection
Safety thermostat with manual reset
Operating conditions
Min.÷ max temperature heat pump air intake (90%
R.H.)
°C
-10 ÷ 43
Min. ÷ max temperature installation site
°C
4 ÷ 40
Working temperature
Max. settable water temperature [with E-heater]
(EN 16147:2017)
°C
65 [75]
Compressor
Rotary
Compressor protection
Thermal circuit breaker with automatic reset
Automatic safety pressure switch (high)
MPa
2.5
Automatic safety pressure switch (low)
MPa
0.1
Fan
Centrifugal
Available external pressure of heat pump
Pa
88
Ejection outlet diameter
mm
160
Nominal air capacity
m3/h
360
Motor protection
Internal thermal circuit breaker with automatic reset
Condenser
Aluminium; wrapped externally, not in contact with water
Refrigerant
R513a
Refrigerant charge
g
1100
Global warming potential of the refrigerant
631
CO2 equivalent (CO2e)
t
0.693
Defrosting
Active with “4-way valve”
Sound emission data; EN12102:2013
Sound power Lw(A) indoor
dB(A)
57
Sound power Lw(A) outdoor
63
Automatic anti-Legionella cycle
YES
Water storage tank
Descriptions
HP3.1 260S
HP3.1 260
HP 3.1 200S
HP3.1 200
Water storage capacity
l
251
260
194
202
Solar heat exchanger surface
m2
1.2
n.a.
1
n.a.
Solar heat exchanger volume
l
7.5
n.a.
5.8
n.a.
Corrosion protection
Mg anode Ø33x400 mm
Thermal insulation
50 mm rigid PU
Maximum working pressure – storage tank
Bar
8
Transport weight
Kg
140
119
121
101
*The output data refers to new appliances with clean heat exchangers!!!
The EVHP heat pump is a device intended for domestic use in conformity with the following European directives:
•
2012/19/ЕU Directive on waste electrical and electronic equipment (WEEE);
•
2011/65/EU Directive on the restrictions of use of certain hazardous substances in electric and electronic equipment
(RoHS);
•
Directive 2014/30/EU - Electromagnetic compatibility (EMC);
•
Directive 2014/35/EU – Low Voltage Directive (LVD);
•
Directive 2009/125/EC Eco design Requirements.
The degree of protection of the equipment is equal to: IPX4.
4. IMPORTANT INFORMATION
4.1.
Conformity with European regulations
4.2.
Degrees of protection provided by enclosures
Summary of Contents for HPWH 3.1 200 U02
Page 2: ......