AMETEK CTS
NSG 3040A, 3060A series
Operating Manual
V 1.04
74 / 157
8.6.
Ring wave Generator as per IEC 61000-4-12
The ring wave module is only for NSG 3060A series available.
Test Level
NSG 3060 series
Open circuit voltage V
200 V
– 6600 V ± 10% Step 1 V
Voltage
Wave shape (open circuit)
Rise time
0.5 μs ± 30% (first peak)
Oscillation frequency
100 kHz ± 10%
Decaying
Peak 2 to peak 1 = 40 - 110%
Peak 3 to peak 2 = 40 - 80%
Peak 4 to peak 3 = 40 - 80%
Current
Wave shape (short circuit)
Rise time
0.2 μs < tr <= 1.0 μs
Oscillation frequency
100 kHz ± 10%
Source impedance Z
12
, 30
, 50
Peak current
As per selected source impedance
Polarity
Positive, negative, alternate
Trigger
Trigger of pulses
AUTO, MAN
Phase angle synchronization A
0° - 360°, resolution 1°
Repetition tr
10 s* - 9999 s
Number of cycles (event) n
1 - 99,999, selectable
Outputs
Direct
Via HC-COM, safety lab connectors
Coupling mode
IEC:
L-N, L-PE, N-PE, L+N-PE
ANSI: L-N, L-G, N-G, L+N-G
CRO trigger
5 V trigger signal for oscilloscope
Test Routines
Quick Start
Immediate start, all parameters adjustable during a running test
Standard test routines
IEC 61000-4-12 one level: Selectable level 1 to 4
separated to (AC / DC)
IEC 61000-4-12 all levels: Starts from lowest level to selected level
IEEE STD C 62.41.2 Cat A, B Power lines
IEEE STD C 62.41.2 Cat A, B Signal lines
IEEE STD C 62.41.2 Cat A, N_G Nearby Power / Signal
IEEE STD C 62.41.2 Cat A, N_G Far Power / Signal
IEEE STD C 62.41.2 Cat A, N_G All Power / Signal
* depends on charging voltage