6.7.2. Adjustment procedure for tapped transformers with analogue DC control voltage
For adjust a tapped transformer, select first the device to adjust in:
Menu / Setup / Transformers / Variable
The tapped transformer is programmed that the
nominal voltage
corresponds to
10.0V dc
as
100%
for
set. The settings are defined as following:
Position
ref dc voltage
80%
8.00 V ± 0.35V
70%
7.00 V ± 0.35V
40%
4.00 V ± 0.35V
Example for automatic tapped transformer
TVT 1-250-16.1
1.
Make a
click
,
Long click
into the device or
press
CHANGE
button for change into the
software setup.
This will rotate the screen and opens the
configuration parameter of the device.
Adjustment procedure
The 100% value of the tapped transformer must
correspond to the actual nominal voltage of the EUT.
3.
Press
230 V
for adjust the 100% voltage
4.
Enter the nominal EUT voltage used for the test
(
100 V, 115 V, 220 V or 230 V
) and confirm
with
OK
.
5.
Confirm and exit with
OK