PORTABLE PROGRAMMER
13
3.4.5
Version
By selecting the Version function of the configuration menu with the Up or Down cursor keys
and pressing ENTER, the portable programmer shows us its manufacture version.
To accept, we press
ý
(F5) and we go back to the main screen of the Portable Programmer.
3.5
Doors Menu
By pressing F2 on the main screen of the Portable Programmer we access the Doors menu.
This menu includes the ensuing operations:
Update
Initialise
Open
Test
On Line Address
To carry out the functions
Update
,
Initialise
and
Open
successfully the
Authorisation Key
of
the installation must be inserted on the Portable Programmer.
If we try to do any of these operations
without
inserting the
Authorisation Key
on the PP we
will see an
Error
message such as the one in the following illustration:
3.5.1
Update
The Update function is used when we need to transfer changes made in the locking plan of a
door to a cylinder, lock or wall reader. That is, it is a cylinder or lock that has already been
"initialised" and therefore belongs to the installation.
Once we have made the necessary changes in the TS1000 management software, we send
the data to the portable programmer. From there they are transmitted to the cylinder or lock by
means of the Update function.