22 

 

 

TECHNICAL DATA 

Parameter 

Unit 

Ecocondens 100  Ecocondens 80 

E n e r g y   p a r a m e t e r s 

Nominal boiler thermal power at 80/60

C (modulated) 

kW 

17-100 

17-80 

Nominal boiler thermal power at 50/30

C (modulated) 

kW 

19 

 110 

19-88 

Nominal heat load 

kW 

18 

 103 

18-82 

The efficiency of the boiler at nominal load and average heating water temperature 70

C

 

97 

The efficiency of the boiler at partial load and return water temperature 30

C

 

107 

Modulation range 

17 

 100 

21 

 100 

Gas category 

--- 

II

2E3P; 

II

2E3B/P

 

Gas consumption

1)

                  natural gas :  

2E-G20 

 20mbar 

 

 

                 natural gas:  

2E-G20 

 13mbar 

 

 

                 liquefied gas :  

3P-G31 

 37mbar 

 

 

                 liquefied gas :  

3B/P-G30 

 30mbar 

m

/ h 

m

/ h 

m

3

 / h 

m

3

 / h 

6,5 
6,5 

2,5 (4,7) 
1,9 (4,8) 

5,6 
5,6 

2,2 (4,1) 
1,6 (4,2) 

1)

) Consumption of different types of gases are given for reference gases in the reference conditions (dry gas 15

°C, pressure 1013 mbar) 

with 107% of the 

efficiency of the boiler and partial load (arithmetic mean of min and max load) at return water temperature of 30

°

C.

 

Nominal kinetic pressure in front of the boiler for gas:  

2E-G20 

 

 

 

 

 

 

2E-G20 

 

 

 

 

 

 

3P-G31 

 

 

 

 

 

 

3B/P-G30 

Pa (mbar) 

2000 (20) 
1300 (13) 
3700 (37) 
3000 (30) 

Max temperature (central heating) 

80 

Standard / reduced adjustable temperature 

20 ÷ 80

 

Pump head (at flow = 0 m

3

/h) 

kPa (bar) 

80 (0,8) 

E n v i r o n m e n t a l     p r o t e c t i o n 

Emission of  NOx  (natural gas) 

Class 

Class NO

x

 

 6 

Emissions of nitrogen oxides 

mg/KWh 

≤ 

50 

The pH of the condensate (natural gas) 

 

Max. amount of condensate (natural gas) 

l/h 

15 

12 

H y d r a u l i c   p a r a m e t e r s 

Hydraulic resistance of the boiler at the heating water flow rate 10 dm

3

/min 

kPa (mbar) 

 

 

Operating pressure 

MPa (bar) 

0,4 (4) 

Amount of water in the boiler 

10 

E l e c t r i c   p a r a m e t e r s 

Type and supply voltage 

~  230 ±10%/ 50Hz

 

Degree of protection 

 

IPX4D 

Integrated fuse 

3,15 

Power consumption 

350 

Type of flame sensor

 

 

ionization 

P a r a m e t e r s   o f   f l u e   g a s 

Type of flue gas-air installation (according to PN-EN 483) 

--- 

B

23

, C

13

, C

33

, C

43

, C

63

 

Max. flue gas flow 

kg/h 

157 

120 

Min. flue gas flow 

kg/h 

32 

Max. flue gas temperature / limiter temperature 

85 / 115 

Min. flue gas temperature 

40 

M o u n t i n g    d i m e n s i o n s 

Mounting dimensions 

mm 

Fig. 3.3.1 

Connection to the chimney duct 

mm

 

Φ

 100 

Connection  of heating water (CH) -- gas 

inch 

G5/4” 

-- 

G1”

 

Dimensions (width x height x depth) 

mm 

540 x 810 x 545 

Boiler weight 

kg 

84 

P a r a m e t e r s    r e q u i r e d    b y    R e g u l a t i o n    8 1 3 / 2 0 1 3 

Efficiency: 

η

η

1

 

 

 

87 
95 

Sound power level L

WA

 

dB 

65 

62 

The manufacturer reserves the right to make changes in the construction of the boiler, which are not mentioned herein and have no influence on the technical 
and functional characteristics of the product.

Summary of Contents for ECOCONDENS CRYSTAL 100

Page 1: ...INSTRUCTION MANUAL INSTALLATION OPERATION AND MAINTENANCE Gas fired condensing central heating boilers SYSTEM BOILERS ECOCONDENS CRYSTAL 80 ECOCONDENS CRYSTAL 100...

Page 2: ...lters are not included in a basic boiler equipment An example of connecting a boiler to these systems is presented on fig 3 5 1 All defects caused by lack of filters on central heating or gas supply w...

Page 3: ...nnecting the boilers in the cascade system 10 4 BOILER ADJUSTMENT AND PRELIMINARY SETTING 10 4 1 INTRODUCTORY REMARKS 10 4 2 ADJUSTING THE BOILER TO COMBUST ANOTHER TYPE OF GAS 11 BOILER CAN BE ADJUST...

Page 4: ...esign and technical specifications of the boiler 2 2 1 Main units of the boiler 2 1 Flue gas water heat exchanger 2 2 Temperature limiter of flue gas 2 3 Temperature limiter of air collector 2 4 Ignit...

Page 5: ...parameter P06 If the heating water temperature exceeds 97 C an additional temperature limiter is activated the burner is turned off until the hot water temperature drops below 81 C The system of conti...

Page 6: ...he boiler from the SUMMER function CH only to the WINTER function CH and DHW A 3sec The entrance to the TEST mode B The reset the displayed error B 3sec Preview of the parameters C Turns on or off the...

Page 7: ...This prepared cables connect according to Fig 3 1 3 1 Fig 3 1 3 1 Wire colors L brown N blue PE yellow green If you need to replace the supply wire use a minimum cord of 3 x 0 75 mm2 The boiler supply...

Page 8: ...ing the back and bottom of the boiler Due to the heavy weight 2 people are required Fig 3 3 1 Mounting dimensions Mounting method on hooks Mounting method with hanger Fig 3 3 2 Mounting method Fig 3 3...

Page 9: ...n are not used as grounding the electrical installation Connect the outlet of safety valves to the floor drain to avoid flooding the room where the boiler is installed as a result of protection device...

Page 10: ...a blowing fan 3 The boiler is designed for cooperation with the flue gas air system with a diameter of 100 flue gas and air and in a collective cascade system where the flue gas exhaust from a single...

Page 11: ...he sum of the lengths of the flue gas air system when the elbow is mounted on the flue gas system or the air supply system to the boiler Table 3 8 3 1 Reduce the length of the installation elbows Exam...

Page 12: ...iler connection with PC MASTER and SLAVE communication connectors are not located in the control console casing Connectors appropriately described are located in bulk inside the boiler Fig 3 9 1 1 Des...

Page 13: ...r in tank EP External cascade pump ES Outdoor temperature sensor CS Temperature sensor in supply collector 3W three way valve Boilers cooperating in the cascade system are connected in series by a cab...

Page 14: ...ctrical installation was made in accordance with applicable regulations the correctness of connections between the boiler and the chimney was checked and confirmed by a qualified chimney service 4 3 B...

Page 15: ...mming mode is switched off 4 5 1 Preview of parameters value You can review the parameter values without the need of change To do this use the B 3sec button After starting LOCAL INSTALLATION mode the...

Page 16: ...ow pressure fill the installation with a filling valve mounted on the installation Start the boiler in the TEST service mode the boiler will start the circulation pump and start the ignition Due to la...

Page 17: ...de The symbol W11 shown on the picture will appear on the screen Press B button to activate the boiler 5 4 Diagnosis When the operation of the boiler will be incorrect the display shows the symbol E a...

Page 18: ...ctrical connections Error 96 description When the P14 parameter is set on a value other than zero the controller does not detect the presence of the sensor closed open Please check the sensor ES conne...

Page 19: ...ont cover 1 Loosen the screws K1 2 Pull the cover behind its lower edge to release from the latches 3 Move the cover up Dismantling the side cover 4 Unscrew the screws K2 5 Move the cover up Fig 6 1 1...

Page 20: ...gas 6 1 3 Thermal protection of the heat exchanger The heat exchanger is equipped with thermal protection BW1 and BW2 protecting against improper assembly of the exchanger If the exchanger is mounted...

Page 21: ...ceeding the limits of temperature protection against exceeding the pressure limits check whether vents are present with correct dimensions and operating according to the installed device In this regar...

Page 22: ...ELV Contact Thermal fuse item 2 2 Supply voltage from the controller SELV Activation temperature 115 C Return NTC sensor item 2 14 Supply item 2 15 Supply voltage from the controller SELV 12K 25 C 363...

Page 23: ...e the power level with D and E buttons by 1 use F button to set the min power or G button to set the max power The PWM signal for the cascade pump is selected according to the operation algorithm of b...

Page 24: ...g 7 2 3 2 1 Diagram of connecting boilers for DHW needs in divided configuration with one three way valve Diagram of connecting 4 boilers two of which are intended for heating DHW Each boiler is equip...

Page 25: ...E n v i r o n m e n t a l p r o t e c t i o n Emission of NOx natural gas Class Class NOx 6 Emissions of nitrogen oxides mg KWh 50 The pH of the condensate natural gas 5 Max amount of condensate natu...

Page 26: ...ly H Flue gas temperature limiter RELAY Relay of the pump 5A ALARM Error information connector PWM PWM pump control G1 Protection against heat exchanger overheating 2xF2 5A Fuses in control panel RT T...

Page 27: ......

Page 28: ......

Reviews: