40
Declaration of Performance
TT80-CPR-2018-Version5
Product:
Product type/application: Room heater burning solid fuel without hot water supply
Type:
TT80: S01-680 Black
TT80: S01-681 Grey
TT80S: S01-682 Black
TT80S: S01-683 Grey
Fuel:
Wood
Productions no.
Please see nameplate on the back of the oven
Manufacturer:
TermaTech A/S
E-mail:
Gunnar Clausens Vej 36
Web:
www.termatech.com
8260 Viby J
Tel.:
+45 8742 0035
Denmark
Certification and requirements:
AVCP system:
System 3
European standard:
DS/DIN/EN 13240:2001 + A2:2004/2007
Certification:
Technologic Institute,
notified body no. 1235, has performed determination of
the
product type and declared performance on the basis of type testing and
issued test report no.
300-ELAB-2358-EN
.
Declared performance:
The undersigned is responsible for the manufacturing and conformity with the declared performance.
08.01.2019
Søren Toft______________________________
Essential characteristics
Performance
Harmonised technical
specification
Reaction to fire
AI
DS/DIN/EN 13240:2001
+ A2:2004/2007
Distance to combustible materials
Rear: min. 75mm
Sides: min. 300mm
Other safety distances – please see User
and mounting manual
Emission of combustion products CO = 0,076%
NOx = 86 mg/m³
OGC = 85 mgC/Nm³
PM = 15 mg/m³
Risk of burning fuel falling out
Passed
Surface temperature
Passed
Clean ability
Passed
Mechanical strength
Passed
Emission of hazardous materials
Passed
Flue gas temperature
226° Celsius
Output
5,5 KW
Energy efficiency
81 %