Operator's Manual
First Edition • First Printing
Part No. 216062
15
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations, i.e. 29 CFR 1910.333,
and the following chart.
Line Voltage
Required Clearance
0 to 50kV
10 ft
3.0 m
>50 to 200kV
15 ft
4.6 m
>200 to 350kV
20 ft
6.1 m
>350 to 500kV
25 ft
7.6 m
>500 to 750kV
35 ft
10.7 m
>750 to 1000kV
45 ft
13.7 m
>1000kV
See below
For power lines over 1000 kV, the minimum
clearance distance must be established by the
utility owner/operator or registered professional
engineer who is a qualified person with respect to
electrical power transmission and distribution.
Allow for platform movement, electrical line sway or
sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Work Area Safety