March 2022
Maintenance Manual
Performance Specifications
Part No. 1268489GT
S
®
Booms • Z
®
Booms
1
Secti on 2
Perfor man ce Speci ficatio ns
Function Speeds - S-100, S-
105 and S-100HD Models
Note: Function speeds are maximum from platform
controls with maximum rated load in platform.
Function speeds are shown in seconds.
Primary boom up/down,
(retracted)
80 - 88
Primary boom up/down,
extended to >4 ft / >1.2 m
(time from fully stowed to the
fully raised position)
100 - 100
Primary boom up/down,
extended to >80 ft / >24.4 m
(time from 53° envelope limit to
the fully raised position)
50 - 55
Primary boom extend,
fully raised position
(0 to 100 ft / 0 to 30.5 m)
120 - 140
Primary boom retract,
fully raised position
(100 to 0 ft / 30.5 to 0 m)
120 - 140
Jib boom up/down,
(S-105 models)
28 - 32
Turntable rotate, 360°
boom horizontal and fully
retracted
170 - 190
Turntable rotate,
boom horizontal and extended
>0 ft / >0 m
63 - 70
drive enable to drive enable
Turntable rotate,
boom fully raised and extended
>80 ft / >24.4 m
109 - 120
drive enable to drive enable
Platform rotate
18 - 22
Platform level
(10° range of motion)
ANSI/CSA
AS/CE
3 - 5
20 - 22