Maintenance Manual
March 2022
Quarterly Maintenance Procedures
102
S
®
Booms • Z
®
Booms
Part No. 1268489GT
Q-36
Inspect and Adjust the Boom
Extend/Retract Cables - All
Models
Genie specifications require that this procedure be
performed quarterly for the first year of ownership
or after the boom extend or retract cables have
been replaced.
After the first year this quarterly inspection is not
required. Refer to the Annual Inspection procedure
appropriate for your machine.
Manufacturers specifications require that this
procedure be performed by personnel that are
competent in cable / wire rope and sheave
inspection.
Note: Additional or more frequent
inspections may be required due to the
following:
•
exposed to hostile or corrosive
environmental conditions.
•
boom is overloaded
•
sustains a shock load
•
electrical arcing
•
unused for extended periods
The boom extend/retract cables and sheaves are
responsible for the extension and retraction of the
boom tubes. Inspecting for foreign objects,
damage and/or improper adjustment of the boom
extend/retract cables and related components on a
regular basis is essential to good machine
performance and safe machine operation. The
boom extend and retract functions should operate
smoothly and be free of hesitation, jerking and
unusual noise.
1 Refer to the appropriate procedure for your
model:
A-11
All S-60, S-65, S-80 and S-85
A-12
S-100/105/120/125, S-100HD, S-120HD, SX-
105XC and SX-125XC
A-13
SX-135XC, SX-150 and SX-180
Summary of Contents for Genie Lift Guard S-40