March 2022
Maintenance Manual
Quarterly Maintenance Procedures
Part No. 1268489GT
S
®
Booms • Z
®
Booms
105
Note: Perform this procedure on a firm, level
surface with the machine in the stowed position.
1 Place the machine on a firm surface that has
a side slope greater than 2° (6.5 inches /
16.5 cm) but less than 5° (16 inches /
40.6 cm).
2 Place a digital level that has been calibrated
to gravity on the X axis of the turntable.
positive degree side slope
negative degree side slope
3 Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both ground and platform controls.
4 Press the
Maintenance
button and select
Real
Time Data
. Navigate to the
Turntable Tilt Roll
Data
.
Result: The reading at the display and digital
level is within ± 1° of each other.
Result: The reading at the display and digital
level is greater than ± 1° of each other.
The
level sensor must be calibrated. Refer to
Repair Procedure in the appropriate Service
and Repair Manual for your machine,
How to
Calibrate the Turntable Level Sensor
.
Tip-over hazard. If the X axis is
not within ± 1°, failure to
properly calibrate the level
sensor could cause the machine
to tip over resulting in death or
serious injury. Refer to Repair
Procedure in the appropriate
Service and Repair Manual for
your machine,
How to Calibrate
the Turntable Level Sensor
.
5 Place the machine on a firm surface that has
an uphill or downhill slope greater than 2°
(6.5 inches / 16.5 cm) but less than 5°
(16 inches / 40.6 cm).
6 Navigate to the
Turntable Tilt Pitch
screen.
Summary of Contents for Genie Lift Guard S-40