Maintenance Manual
March 2022
Quarterly Maintenance Procedures
98
S
®
Booms • Z
®
Booms
Part No. 1268489GT
63 Disconnect the circle-end axle extend safety
switch LSAX1ES and install a wire jumper
between pin 1 and pin 2 of the Deutsch
connector.
64 Activate the function enable/high RPM button
and attempt to extend the boom.
Result: The boom should not raise to more
than 11°.
Result: If the boom continues to raise, the
LSAX1ES or LSAX2ES switch are out of
adjustment or the wiring circuit is faulty and
will need to be replaced or repaired.
Bodily injury hazard. If the boom
raises to more than 11°, stop
immediately and lower the boom
until the boom is less than 11°.
Failure to lower the boom could
result in death or serious injury.
65 Remove the wire jumper installed in step
63 and connect the Deutsch connector to
LSAX1ES.
66 Disconnect the circle-end axle extend safety
switch LSAX2ES and install a wire jumper
between pin 3 and pin 4 of the Deutsch
connector.
67 Activate the function enable/high RPM button
and attempt to extend the boom.
Result: The boom should not extend to more
than 3 feet / 0.9 m.
Result: If the boom extends to more than
3 feet / 0.9 m, the LSAX1ES or LSAX2ES
switch are out of adjustment or the wiring
circuit is faulty and will need to be replaced or
repaired.
Bodily injury hazard. If the boom
extends to more than 3 feet/
0.9 m, stop immediately and
retract the boom until the boom
is extended to less than 2 feet/
0.6 m. Failure to retract the
boom could result in death or
serious injury.
68 Remove the wire jumper installed in step
63 and connect the Deutsch connector to
LSAX2ES.
69 Disconnect the circle-end axle extend safety
switch LSAX2ES and install a wire jumper
between pin 1 and pin 2 of the Deutsch
connector.
70 Activate the function enable/high RPM button
and attempt to raise the boom.
Result: The boom should not raise to more
than 11°.
Result: If the boom continues to raise, the
LSAX1ES or LSAX2ES switch are out of
adjustment or the wiring circuit is faulty and
will need to be replaced or repaired.
Bodily injury hazard. If the boom
raises to more than 11°, stop
immediately and lower the boom
until the boom is less than 11°.
Failure to lower the boom could
result in death or serious injury.
71 Remove the wire lumper installed in step
69 and connect the Deutsch connector to
LSAX2ES.