March 2021
Service and Repair Manual
Type "FXXX" Faults
Part No. 1272217GT
GS
™
-30 • 32 • 46 • 47
175
Type "FXXX" Faults, continued
DTC
Number
Message on
GCON LCD
Description
Possible Causes
Failure Mode
F012:
GS-3232
F012:SENSORFAULT
LEVEL PITCH:BAT+
Short circuit of the Level Pitch Sensor circuit
to battery positive.
• Short circuit in the level pitch sensor circuit.
• Faulty level sensor.
• GCON ECM.
All functions inhibited.
F013:
GS-3232
F013:SENSORFAULT
LEVEL PITCH:BAT-
Short circuit of the Level Pitch Sensor circuit
to battery negative.
• Short circuit in the level pitch sensor circuit.
• Faulty level sensor.
• GCON ECM.
All functions inhibited.
F014:
GS-3232
F014:SENSORFAULT
LEVEL ROLL:BAT+
Short circuit of the Level Roll Sensor circuit
to battery positive.
• Short circuit in the level roll sensor circuit.
• Faulty level sensor.
• GCON ECM.
All functions inhibited.
F015:
GS-3232
F015:SENSORFAULT
LEVEL ROLL:BAT-
Short circuit of the Level Roll Sensor circuit
to battery negative.
• Short circuit in the level roll sensor circuit.
• Faulty level sensor.
• GCON ECM.
All functions inhibited.
F016:
GS-3232
F016:SENSORFAULT
LF RIGGER:BAT+
Short circuit of the Left Front Outrigger
Sensor circuit to battery positive.
• Short circuit in the left front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Left front outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
F017:
GS-3232
F017:SENSORFAULT
LF RIGGER:BAT-
Short circuit of the Left Front Outrigger
Sensor circuit to battery negative.
• Short circuit in the left front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Left front outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
F018:
GS-3232
F018:SENSORFAULT
RF RIGGER:BAT+
Short circuit of the Right Front Outrigger
Sensor circuit to battery positive.
• Short circuit in the right front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Right front outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
F019:
GS-3232
F019:SENSORFAULT
RF RIGGER:BAT-
Short circuit of the Right Front Outrigger
Sensor circuit to battery negative.
• Short circuit in the right front outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Right front outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
F020:
GS-3232
F020:SENSORFAULT
LR RIGGER:BAT+
Short circuit of the Left Rear Outrigger
Sensor circuit to battery positive.
• Short circuit in the left rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Left rear outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
F021:
GS-3232
F021:SENSORFAULT
LR RIGGER:BAT-
Short circuit of the Left Rear Outrigger
Sensor circuit to battery negative.
• Short circuit in the left rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Left rear outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.
F022:
GS-3232
F022:SENSORFAULT
RR RIGGER:BAT+
Short circuit of the Right Rear Outrigger
Sensor circuit to battery positive.
• Short circuit in the right rear outrigger sensor
circuit.
• Faulty pressure transducer.
• GCON ECM.
Right rear outrigger
inhibited if outrigger
extend is activated.
Outrigger can still be
retracted.