V3.03 - released 2006-03-20
•
Automatic aspect ratio 4:3/16:9 encoding added.
If WSS (wide screen signal) is found in video input signal and encoder is set to "Auto"
aspect ratio, the ENC-100 will set the correct aspect ratio flag within MPEG TS stream.
WSS detection and auto aspect ration for both PAL and NTSC.
•
Fixed aspect ratio encoding option for 4:3 or 16:9 added.
•
Full SNMP remote control added and MIB files. All settings can be remotely configured
by 3
rd
party SNMP manager.
•
SNMP status traps added, for monitoring ENC-100 on/off and GPI status changes.
•
Automatic recognition and switching for Black/White and Color video signals.
•
Grey screen added. Upon video loss users can choose between freeze frame of last
video frame or display of a grey screen. Audio encoding will continue.
•
New update for audio encoding chip and codec installed (LM4549A(VH)).
•
Closed Captioning support. Supported only for NTSC. Closed Captioning data must be
present within video signal.
•
Improvements for VBR encoding added through redefined MPEG quantization factors.
•
Power-down, power-saving support for ENC-100-SDI version added.
•
Low bitrates issues due to startup delay have been fixed.
•
Issue of simultaneous video input loss and network loss has been fixed.
•
Metadata setting for MPEG TS stream flags added:
PMT ID (Program Map Table) and Program ID can now be added/adjusted manually to
identify and tag a stream.
V3.04 - released 2006-03-20
•
New default settings e.g.: IP 172.16.20.100, Destination IP 239.252.20.100
V3.05 - released 2006-06-27
•
XPlayer-Link added. For viewing and monitoring of the ENC-100 Stream. If the
Standalone XPlayer is installed on the client PC, running the webconfig pages, the
XPlayer can directly be launched by a mouse click from the user interface.
•
Compensation of horizontal jitter, caused by some analog input devices. This jitter is
compensated via Time-Base-Correction.
V3.06 - released 2006-10-09
•
Auto Reconfigure added. Resets the PCR every 24 hours. Thereby the PCR-Overflow
can be avoided, which is caused by MPEG standard.