SUPERVISOR CONTROLS
54
Tennant T300e/T300 (03- 2015)
T300 MODEL WITH PRO-PANEL CONTROLS
There are two types of user modes that will interface
with the operator home screen:
Operator Mode -
Capable of machine operation with
permissions and restrictions controlled by the
supervisor.
Supervisor Mode -
Capable of machine operation
with full use of all controls, along with configuring
permissions and restrictions for the operator mode.
A new machine from the factory will automatically start up
in the supervisor mode with a preassigned default
supervisor profile. The machine’s factory-assigned
supervisor login number is “1234”. This login number is
not required until it’s enabled. The default supervisor
profile name and login number can be changed as
described in this section. If the new assigned supervisor
mode login number is forgotten, use the recovery login
code 836626826.
To enter the supervisor controls follow the instructions
below:
1. Park the machine on a level surface and turn the
key to the on ( I ) position. The home screen will
display at start up (Figure 141). This is the factory
default screen at start up.
NOTE: If a login screen appears at start up. Enter
the factory-assigned supervisor login number or
your saved personalized supervisor login number
to access the operator home screen.
2.
Press the settings button located on the
home screen (Figure 141).
FIG. 141
3.
Press the Setup button to access the Setup
screen (Figure 142). The Setup screen is only
accessible with an assigned supervisor login
number.
FIG. 142
4. The Setup screen allows supervisor access to the
following controls as described below.
FIG. 143
Add/Edit Profiles
- Provides the capability
to add, edit, copy or delete user profiles.
Battery Type
- Use this to select battery
type installed in machine. This ensures the
on-board battery charger charging profile is
properly programmed to your battery type. See
BATTERIES.
Enable Login
- Activates a required login
number at machine start up for all user profiles to
operate machine.
Calibrate Touch Icon
- Use this to calibrate
the touch screen if the touch points become
misaligned.
Factory Reset
- Resets the supervisor login
number back to the factory default number 1234,
removes user profiles and resets any custom
preset zone setting names back to the factory
preset names.
To Add/Edit User Profiles
Before adding new user profiles, it is recommended to
configure the four Zone Settings in advance (See
CONTROL PANEL OPERATION).
1.
Press the “Add/Edit Profiles” button to enter
the user profile settings (Figure 144).
FIG. 144