MAINTENANCE
40
Tennant T300e/T300 (03- 2015)
4. Disconnect the battery cable, power cord and wire
harness from charger. Using a T25 star
screwdriver, remove the four screws that mount
charger to machine (Figure 121). Remove charger
from machine.
FIG. 121
5. Remove the black cap from bottom side of charger
to access the profile dial (Figure 122)
FIG. 122
6. Using a small standard screwdriver, turn the dial to
the appropriate battery type according to the
following chart (Figure 123).
FIG. 123
Dial
Position
Battery Description Settings
with AH Ranges
0
Factory setting*
1
Wet, Trojan 105- 155 AH
2
Wet, Enersys/Tab 105- 155 AH
3
AGM, Discover 80- 150 AH
4
AGM, Fullriver 80- 150 AH
5
AGM, TPPL, Enersys 20- 40 AH
6
Gel, Sonnenschein 80- 150 AH
* The factory setting, dial position “0”, is pre-programmed
to accommodate the battery type supplied with new
machine. After the dial is changed from the factory
setting, it should not be returned to “0” otherwise battery
damage may result.
7. Replace the black cap on charger, reinstall battery
charger and replace control console.
8. Reconnect the battery cable connection.
T300 Model with Pro-Panel Controls -
NOTE: To perform this procedure, machine must be in
supervisor mode.
See SUPERVISOR CONTROLS
instructions at back of manual.
To change the on-board battery charger settings for a
different battery type :
1. Turn the key to the on position.
2.
Press the settings button located on the
home screen (Figure 124).
FIG. 124
3.
Press the Setup button to access the Setup
screen (Figure 125).
FIG. 125
4.
Press the Battery Type button to select the
battery type installed in machine (Figure 126).
FIG. 126