OPERATION
Tennant T300e/T300 (02- 2016)
19
T300 CONTROL PANEL OPERATION
T300 WITH MEMBRANE CONTROL PANEL
(Manual Down Pressure Model)
1. Turn the key to on ( I ) position to power up
machine.
Models equipped with the ec-H2O option - The
ecH2O system will automatically turn on at start up.
A blue ec-H2O icon will appear on the control panel
(Figure 38). This indicates that the ecH2O system
is turned on and ready for operation. To turn off the
ec-H2O system, press the ec-H2O switch located
below the key switch.
FIG. 38
2. Press the solution flow button to increase or
decrease the solution flow rate (Figure 39). The
solution flow indicator will display flow setting.
No LED = No flow, One LED = Low flow, two
LED’s = Medium flow, three LED’s = High flow.
FIG. 39
3. Models equipped with Severe Environment button
option - Press Severe Environment button one
time to dispense cleaning detergent for 30 seconds
(Figure 40). A green LED in the corner will blink
slowly when dispensing. During the last 5 seconds,
the LED will blink rapidly as an alert that the
dispensing is about to stop. For continuous
dispense, press and hold the button for 2 seconds
until LED turns solid green. Press button at
anytime to turn off.
The icon will blink blue when the severe
environment tank needs to be refilled.
NOTE: When the severe environment mode is
turned on, the down pressure and solution flow
settings automatically increase to the high setting.
When turned off, the settings revert back to the
original settings.
FIG. 40
4. Models equipped with Quiet-Mode option - Press
the Quiet-Mode button to reduce the vacuum motor
sound (Figure 41). A green LED in the corner will
turn on when mode is activated. Press button to
turn off.
NOTE: Water pickup will reduce slightly when
Quiet-Mode is activated.
FIG. 41
5. If a machine fault is detected during operation, the
service indicator will light up and begin flashing
(Figure 42). See SERVICE INDICATOR CODES.
If the ec-H2O system detects a fault during
operation, the ec-H2O icon will turn or blink red.
See SERVICE INDICATOR CODES.
FIG. 42
ec-H2O INDICATOR
CONDITION
Solid blue
Normal operation
Blinking blue/red
Water conditioning cartridge
expired. Replace cartridge.
Solid or blinking red
See Service Indicator Codes.