MAINTENANCE
57
450 MM289 (3
−
94)
SOLUTION SYSTEM
RECOVERY TANK
The recovery tank stores recovered solution. The
recovery tank should be drained and cleaned
daily.
NOTE: The water must not be hotter than 55
C
(130
F), or tank damage may occur.
Do not
use
steam to clean the tank.
The vacuum fan inlet screen in the vacuum fan
should be cleaned daily.
The vacuum fan housing contains two check
valves. Check the valves periodically to see that
they move freely up and down. Wipe them off with
a clean cloth.
The recovery tank has one tank float on a
standard machine, and two tank floats on a ES
machine. The tank floats should be cleaned every
50 hours of machine operation.
The tank floats can be cleaned by removing the
right recovery tank access cap, and flushing the
floats with a hose. The tank floats can also be
removed from the tank to be cleaned.
07262
07263
07279