MAINTENANCE
450 MM289 (1
−
92)
58
SOLUTION TANK
The solution tank contains the cleaning solution.
The solution tank does not require regular
maintenance. If deposits form on the bottom of
the tank, rinse the tank with a strong blast of
warm water.
NOTE: The water must not be hotter than 55
C
(130
F), or tank damage may occur.
Do not
use
steam to clean the tank.
The solution tank on machines with the ES
option should be drained and cleaned daily.
SQUEEGEE
The squeegee channels water into the vacuum
fan suction. The front blade channels the water,
and the rear blade wipes the floor.
Check the squeegee blades for damage and wear
daily. Rotate or replace either of the squeegee
blades if the leading edge is torn or worn half-way
through the thickness of the blade.
The squeegee can be adjusted for leveling and
deflection. The deflection of the squeegee blades
should be checked daily, or when scrubbing a
different type of floor. The leveling of the
squeegee should be checked every 100 hours of
machine operation.
REMOVING THE SQUEEGEE
The squeegee can be removed from the
squeegee pivot so the squeegee will not be
damaged during transport of the machine.
1. Turn the machine power off and set the
parking brake if your machine has this
option.
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Set Parking
Brake (If So Equipped), Turn Off Machine And
Remove Key.