MAINTENANCE
53
450 MM289 (1
−
92)
NOTE: If the skirt band needs to be adjusted for a
tighter or looser fit around the scrub head, remove
the band clip from the band and move it to the
next notch. Tighten the skirt band clamp.
6. Turn the machine power on and raise the
scrub brush.
7. Turn the machine power off.
REPLACING THE SCRUB HEAD SKIRT
1. Make sure the scrub head skirt is raised just
off the floor.
2. Turn the machine power off and set the
parking brake if your machine has this
option.
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Set Parking
Brake (If So Equipped), Turn Off Machine And
Remove Key.
3. Loosen the skirt band clamp.
4. Pull the old skirt out from under the skirt
band.
5. Insert the new skirt under the skirt band all
the way around the scrub head.
6. Tighten the skirt band clamp.
7. Adjust the skirt as stated in
ADJUSTING
THE SCRUB HEAD SKIRT
.
07274
07275
07273