OPERATION
450 MM289 (6
−
93)
16
CIRCUIT BREAKERS
The circuit breakers are resetable electrical circuit
protection devices. They are designed to stop the
flow of current in the event of a circuit overload.
Once a circuit breaker is tripped, it must be
manually reset by pressing the reset button after
the breaker has cooled down.
If the overload that caused the circuit breaker to
trip is still there, the circuit breaker will continue to
stop current flow until the problem is corrected.
The circuit breakers are located on the control
panel.
The chart shows the circuit breakers and the
electrical components they protect.
Circuit
Breaker
Rating
Circuit Protected
CB-1
10 A
Controls
CB-2
30 A
Propelling motor
CB-3
35 A
Scrub brush motor
CB-4
25 A
Vacuum fan
SUPPORT ARM
The support arm holds up the solution tank when
the tank is lifted open. The support arm engages
when the solution tank is lifted all the way forward.
The arm is released by pulling on the arm.
STOP ARM
The stop arm prevents the solution tank from
pinching fingers when the solution tank is lowered.
Rotate the arm up to lower the solution tank
completely.
07292
07258
07259