Enter Call-Answered Supervision Pulse Option
Use the following key sequence to enable or disable the call-answered
supervision pulse, select its frequency, and program its duration:
Press:
#
*
18
*
<cas_pls_enable>
*
<cas_pls_freq>
*
<cas_pls_duration>
*
<cas_pls_level> #
The cas_pls_enable value is set to
0
to disable the pulse,
1
to enable
the pulse. If the value is neither 0 nor 1, it will be considered invalid.
The cas_pls_frequency value is set to
0
for 12 kHz,
1
for 16 kHz. If the
value is neither 0 nor 1, it will be considered invalid. The cas_pls_
duration value is programmed in 1 ms increments from
10
to
65535
(10 - 65,535 ms). If the value is not between 10 and 65535, inclusive, it
will be considered invalid. The cas_pls_level can be programmed to
any of the values shown in the table below. If the cas_pls_level is not
between 0 and 6, inclusive, it will be considered invalid. The factory
default is
0
,
0
,
100
,
3
.
<cas_pls_level>
Power (dBm)
0
0 ± 3
1
3 ± 3
2
-6 ± 3
3
-9 ± 3
4
-12 ± 3
5
-15 ± 3
6
-18 ± 3
Enter Line-Reversal Outgoing Option
Use the following key sequence to enable or disable line (tip/ring)
reversal for outgoing calls:
Press:
#
*
22
*
<line_reversal_outgoing> #
The line-reversal outgoing value is set to
0
to disable line reversal,
1
to
enable line reversal. If the value is neither 0 nor 1, it is considered
invalid. The factory default is
0
.
Enter Line-Reversal Incoming Option
Use the following key sequence to enable or disable line (tip/ring)
reversal for incoming calls:
Press:
#
*
23
*
<line_reversal_incoming> #
The line-reversal outgoing value is set to
0
to disable line reversal,
1
to
enable line reversal. If the value is neither 0 nor 1, it is considered
invalid. The factory default is
0
.