24
Configuration and detailed explanation of SMS method is described below. Device always sends the newest coordinate.
Parameter
Description
1. Alarm SMS sending period
Describes time period. After this time is up device sends SMS to numbers entered in
Send alarm to list, when alarm mode is activated. Action will be repeated periodically.
Minimal time period: 30s.
Maximum time period: 2592000s.
2. SMS
Choose format of SMS message, which will be sent when alarm mode is activated.
3. Send alarm to
Contact list, which will receive SMS messages, one by one from top to bottom can be
entered here.
Maximum number of numbers is 5.
Operation
Alarm mode operation and activation method can be selected depending on user needs. Alarm function has higher
priority than other functions. If functions are working simultaneously saving periodical and alarm data, alarm data
saving will take priority to save alarm data first.
The use of PreAlarm is recommended when using alarm function. PreAlarm is made to prevent accidental alarm
activation. Alarm activation can be canceled until PreAlarm time ends because PreAlarm is activated first. User can avoid
false alarm using this function. Detailed operation of alarm mode is depicted in a picture “Operation of alarm mode”.