For example: *6*18# = 1.8 seconds
This value may need to be adjusted depending on the requirements of your
telephone system.
Function 8: Idle Detect Time (Silent Interval)
The M-106E will monitor the line for the specified period of silence, do a
switchhook flash, then look for dial tone and, when dial tone is detected for 5
seconds, will disconnect. The default setting for this function is disabled.
To set the length of time that silence must be present on the line before the unit
will look for dial tone, enter:
*8*TT#
where:
TT may be 0-99 minutes.
In some installations (including those in which the incoming line is a loop start
line and the central office is not able to force disconnect), the M-106E may be
unable to disconnect without special procedures such as this one.
To disable this feature (default), enter:
*8*0#
Function 9: Dial Tone Detect Time (Initiate Disconnect)
This function forces the M-106E to disconnect after dial tone has been present
for the specified time. (Default is disabled.) In some installations (including
those in which the incoming line is a loop start line and the central office is not
able to force disconnect), the M-106E may be unable to disconnect without
special procedures such as this one.
To specify the time dial tone must be present, enter:
*9*TT#
where:
TT = 5 through 20 (seconds).
To disable disconnect on dial tone detection (Default), enter:
*9*0#
Function 15: Password Access Enable/Disable
Requires the caller to enter a password in order to access the M-106E. To
operate the M-106E without password access, disable this function.
To enable the password access requirement (default), enter:
*15*1#
To disable the password access requirement, enter:
*15*0#
Chapter 5: Programming the M-106E
106E-101, Issue 1