Step 8: Reaccess unit
•
Reaccess the unit. After the unit ring trips, the red IN and OUT indicators
should light and you should hear dial tone from the outgoing line.
Step 9: Make test call
•
Place a call through the M-106E and verify that the voice levels are
satisfactory. If not, follow the instructions for the model you are using:
•
M-106-01E units:
Press the front panel switch to PROGRAM until the
green light flashes. Then place a call to the unit and adjust the amplifier
gain as instructed in Chapter 6, Function 12.
-or-
M-106-05E units:
An amplifier should be added to the unit. This requires a
factory upgrade; see Chapter 7 for information on returning units.
•
The unit is now ready for use. If the above procedures cannot be
completed successfully, press the front panel switch to PROGRAM until
the green light flashes quickly. Repeat Steps 1-9 before going to the
troubleshooting procedures.
•
Refer to Chapter 5 for information on how to set other M-106E functions if
required.
Operation WITH a Single Password
Remote Programming Disabled for this operation. Perform the following steps
for operation with password access:
Step 1: Press switch to READY
•
Press the front panel switch to READY.
Step 2: Connect power cord
•
Connect the transformer and power cord between the unit and a 120 VAC
outlet. The green light should begin flashing.
Step 3: Connect incoming line
•
Connect the incoming telephone line to the IN jack on the back of the
M-106E. Determine the telephone number and write it in the blank space:
.