Section 13: Deep Tech Information and Troubleshooting 286
Is
the
problem
only
with
one
BRI
circuit?
Does
the
problem
move
when
you
switch
the
line
to
another
ISDN
unit?
If
the
problem
remains
with
the
line,
then
call
your
Telco.
If
you
are
supposed
to
be
using
the
Xstream's
built
‐
in
NT1
(i.e.
the
U
interface)
be
sure
to
note
if
you
have
U
Sync
(note
the
green
LED
near
the
U
jack
on
the
rear
of
the
Xstream).
If
you
have
a
fast
blinking
U
Sync
light
the
problem
is
most
likely
your
ISDN
circuit.
If
the
U
Sync
LED
is
lit
solidly,
then
suspect
a
line
configuration
(“provisioning”
in
Telco
‐
speak)
problem
(also
review
the
information
in
the
previous
questions).
Are
you
using
the
Xstream’s
internal
NT1
?
(USA
&
Canada
only)
The
LED
indicator
of
the
status
of
the
ISDN
connection
is
on
the
rear
panel
near
the
U
jack.
If
the
circuit
is
inactive,
the
LED
will
remain
in
the
rapidly
flashing
state.
This
state
indicates
a
loss
of
the
ISDN
BRI
circuit
at
the
lowest
(physical)
level.
Try
another
line
cord
or
try
another
line
in
to
see
if
the
same
thing
happens.
If
the
NT1
can
contact
the
central
office,
the
LED
will
blink
slowly
(about
1
Hz).
If
the
LED
remains
in
this
state
there
is
an
internal
Xstream
problem
or
you
could
be
connected
to
the
wrong
jack
on
the
back
(Users
in
USA
&
Canada
should
be
using
the
lower,
RJ11
style,
jack).
The
LED
will
come
on
solidly
when
all
handshaking
is
completed
and
the
basic
(low
level)
line
connection
is
good.
If
the
LED
stays
on,
with
the
ISDN
disconnected,
or
does
not
come
on
at
all,
there
is
a
hardware
problem.
See
above
for
more
on
this
LED.
Condition: Line 1 will accept call however Line 2 will not
Have
you
entered
Directory
numbers
in
the
MSN/DN1
&2
entries
in
the
TEL
menu?
These
are
required
if
you
are
using
DMS
‐
Custom
or
Natl
I
‐
1
for
your
ISDN
type.
Condition: Can place calls, or receive calls, but not both
If
your
line
is
using
National
ISDN
and
your
Telco
is
set
to
DMS
Cust.
,
or
vice
versa,
you
may
see
this
behavior.
Try
the
other
setting.
If
your
line
is
using
National
ISDN
or
DMS
‐
Custom,
you
must
have
your
Directory
Numbers
entered
to
receive
calls.
Condition: System says Ready but attempted calls do not complete (goes back to
Ready or sits at Seize Pending)
Are
your
SPIDs
and
Telco
setting
correct?
We've
included
quite
a
few
useful
tips
above
on
SPIDs
and
on
how
to
guess
your
ISDN
protocol.
If
SPIDs
are
required
and
have
been
omitted
a
false
"Ready"
may
be
displayed.
Can
you
dial
from
Line
1
to
Line
2?
If
you
can
successfully
call
from
one
line
to
the
other,
you
know
that
your
SPIDs
and
ISDN
protocol
settings
for
that
line
are
correct
and
that
the
ISDN
circuit
itself
is
ok.
Summary of Contents for Zephyr Xstream
Page 2: ......
Page 26: ...USER S MANUAL Section 1 QUICK RESULTS 14...
Page 30: ...USER S MANUAL Section 2 INTRODUCTION Getting to Know the Zephyr Xstream 18...
Page 70: ...USER S MANUAL Section 3 GUIDED TOUR of the HARDWARE 58...
Page 144: ...USER S MANUAL Section 6 AUDIO CODING REFERENCE 132...
Page 164: ...USER S MANUAL Section 8 LIVEWIRETM IP Audio 152...
Page 310: ...USER S MANUAL Appendix 1 Codec Interoperability Information 298...
Page 320: ...USER S MANUAL Appendix 3 ISDN Cause Phrases Values 308...
Page 324: ...USER S MANUAL Appendix 4 Known Working SPID Formats by Telco 312...
Page 356: ...USER S MANUAL Appendix 9 Modular Cable Guide 344...