30
| Section 4
In some cases, lines in a hunt group will require that the same (primary Listed Directory
Number) be entered for all lines that are part of the hunt group.
Some versions of the Telos Zephyr and Zephyr Express do not require that Directory
Numbers be entered. This is not true for the Telos iQ6 and other newer products. You must
correctly enter these numbers for the system to work.
IMPORTANT
After you enter (or change) your SPIDs or DN’s you must restart the system to use the new
information. Therefore, once you have entered SPIDs, DNs, or MSNs cycle power off and then
back on. Then go to the ISDN status screen and verify “Ready” status for all channels.
4.2.3 Audio
Nominal Input Level and Meter type
Adjusts to the level expected from the Axia iQ console. It is applied before the send AGC.
Increasing the input level past the correct value will not make the send louder due to the AGC/limiter.
The ballistic (time) characteristic of iQ6 meters changes depending on the Input Level setting. When
-20dBFS is selected, the meter has a VU-standard integration time. When +9dBu PPM is selected, the meter
has a PPM time characteristic.
The usual setting is -20dBFS. The +9dBu PPM setting is intended for Euro installations.
Nominal Output Level and meter type
This adjusts the level for the output.