3.4.- ERROR WARNINGS
When the equipment detects an error in any of the modules or components, it warns the user
through a series of messages as can be seen below:
· NO BAT. :
This message appears when the equipment is switched on and no batteries are detected.
The equipment operates correctly while connected to the mains.
The same message appears when the user wishes to charge the batteries and there are no
batteries connected to the equipment.
· WRONG BATT:
This message appears when the equipment is switched on and when the batteries that are
being used are not the same as the ones that come with the equipment from the factory or
when the position of the configuration microswitches of the battery (side of the equipment)
are not in the correct position. When the equipment displays this error message, it is
impossible to charge the batteries (
see section 3.3.2.6.2
).
· FULL BAT :
This message will appear when the user tries to charge a battery that is already charged.
· EXCES TEMP:
The equipment continuously monitors the temperature. When it is too high, this message
flashes onscreen. If the temperature does not go down, the equipment shuts down
automatically. If the temperature goes down, the message disappears.
If this message appears, it is advisable to improve the conditions in temperature. The user
can carry out various modifications, for example, place the equipment in a more ventilated
area, take away any objects that may be blocking its ventilation, stop charging the batteries
(button
) if the equipment is in use.
If this warning message does not disappear, it is advisable to switch the equipment off while
keeping the external power supply connected
, to facilitate the elimination of the internal
heat.
· ERROR XXXX:
When the equipment is switched on, it checks all of its modules. When it detects an error in
any of these, an
ERROR
message will appear followed by a code. If this happens, please
contact your local Televés distributor, informing him/her of this error code.
· ERR CHARGE:
When the DC adapter is connected to the equipment, this checks the current in the external
powering connector (31). If the equipment detects an erronious current, it warns the user via
an error message which flashes onscreen. The
Ext. Supply
LED will also flash.
· Vext.:
This error message appears when the voltage of the external units is selected and when the
equipment detects a different current in the “F” connector than that selected by the user.
Multimetter FSM 500