Telemark TT-6 Power Supply
TRIANGLE pattern. Note: Triangle is not silkscreened on the
panel, but it is the middle position, similar to the Joystick
Controller Module.
With the MODE switch in the SPIRAL condition, the Longitudinal/Modulation
Frequency knob controls the spiral-collapse frequency, while both Lateral and
Longitudinal Amplitude and Position knobs control the overall size and placement
(in two axis). The Modulation Amp knob controls the depth of spiraling collapse
(how close the beam moves towards the center of the pattern).
With the MODE switch in the MANUAL beam position setting, the Lateral and
Longitudinal Position knobs are used to position the beam; there is no sweeping.
With the MODE switch in the TRIANGLE setting, the Lateral and Longitudinal
Positions, Amplitudes, and Frequencies of the beam are set with the
corresponding knobs. The resulting beam movement is in a diamond(s) pattern.
5
&
6
POSITION - Moves the beam (in two axis-Lateral [left
&
right] and Longitudinal [near
&
far]), or the center position of
patterns.
7
&
8
AMPLITUDE -Adjusts the overall pattern size (in two
axis).
9
&
10
FREQUENCY -Adjusts the sweeping speed(s). When in
Triangle mode, the Lateral and Longitudinal Frequency knobs
operate independently (in two axis). When in Spiral mode, only
the Longitudinal/Mod.Freq. pot (10) controls the spiral-collapse
frequency.
11
MOO AMP - The modulation amplifier knob adjusts the depth of
the spiral's collapse.
Main Cabinet
See Fig. 4-E
1 MAIN CIRCUIT BREAKER - This provides primary circuit
protection. When it is
ON,
AC power is applied to the power
supply. (2-pole single phase, TT-3; and 3-pole three phase,
TT-6)
2
CONTROL POWER - These (1 amp, TT-3; and 2 amp, TT-6)
thermo breakers provide protection for the control circuits. If
they should
TRIP,
their actuators must be pushed in to resume
normal operation.
3
MAIN POWER IND/CA TOR - This LED lights when power is
applied to the control circuits.
4
HIGH VOLTAGE INDICATOR- This LED lights when the high
voltage is turned on.
4-6