0102
Same as 0100, but to charge an external RC timer I/O7 is pulled high whilst sending the data and
left high impedance the rest of the time.
0103
Same as 0101, but to charge an external RC timer I/O7 is pulled high whilst sending the data and
left high impedance the rest of the time.
0108
The unit sends the contents of S2B to the networks sink. If applicable the timer will stop.
Prompt on the sink: <contents of S2B>
0109
The unit sends the contents of S2B to the networks sink. If applicable the timer will restart.
Prompt on the sink: <contents of S2B>
010A
The unit sends the contents of S2C to the networks sink. If applicable the timer will stop.
Prompt on the sink: <contents of S2C>
010B
The unit sends the contents of S2C to the networks sink. If applicable the timer will restart.
Prompt on the sink: <contents of S2C>
0110
Sends the reading of the I/O and the two analogue ports as well as an 8-bit transmission counter
which increments with every transmission to the network‟s sink and if no sink is known the unit will
search for a sink instead. After 3 unsuccessful transmissions the sink is assumed unavailable and
a new sink is searched. If applicable the timer will stop.
Prompt on the sink: NDATA:<EUI64>,<nn>,<xxxx>,<yyyy>,<zzzz>
Where <EUI64> is the senders ID, <nn> is the transmission number, <xxxx> is the reading of the
I/O port, <yyyy> is the reading of A/D0 and <zzzz> is the reading of A/D1
0111
Same as 0110, but if applicable the timer will restart.
0112
Same as 0110, but to charge an external RC timer I/O7 is pulled high whilst sending the data and
left high impedance the rest of the time.
0113
Same as 0111, but to charge an external RC timer I/O7 is pulled high whilst sending the data and
left high impedance the rest of the time.
0120
Sends the contents of S2B as a RAW transmission. If applicable the timer will stop.
0121
Same as 0120, but if applicable the timer will restart.
0122
Sends the contents of S2C as a RAW transmission. If applicable the timer will stop.