In case the local node is not joined to a network scan for and join the next best network and stop
the timer (if caused by a timer)
0016
In case the local node is not joined to a network scan for and join the next best network and restart
the timer (if caused by a timer). By default this action is executed every minute using
timer/counter1 (S1D and S1E).
0017
Allow joining for 60 Seconds (in case it is disabled by setting bit B of S06) and stop timer (if
caused by a timer)
0018
Copy the inputs of the local device to the outputs of the device whose EUI64 is defined in S2B and
stop the timer. This allows a pair of devices to form a remote switch relay.
0019
Same as function 0018 but restart the timer.
001A
Copy the inputs of the remote device whose EUI64 is defined in S2C to the outputs of the local
device and stop the timer.
001B
Same as function 001A but restart the timer.
001C
Clean up the child table by removing children that have not reported in.
001D
Close any open channel.
002x
Toggle I/Ox and stop timer (if caused by a timer)
003x
Toggle I/Ox and restart timer (if caused by a timer)
004x
Flash I/Ox (pull low) for 250ms and restart timer (if caused by a timer)
0100
Sends the reading of the I/O and th
e two analogue ports to the network‟s sink and if no sink is
known the unit will search for a sink instead. After 3 unsuccessful transmissions the sink is
assumed unavailable and a new sink is searched. If applicable the timer will stop.
Prompt on the sink: SDATA:<EUI64>,<xxxx>,<yyyy>,<zzzz>
where <EUI64> is the sender
‟s ID, <xxxx> is the reading of the I/O port, <yyyy> is the reading of
A/D0 and <zzzz> is the reading of A/D1
0101
Same as 0100, but if applicable the timer will restart.