Telegesis (UK) Limited
TG-ETRXn-UG-01-103
33
User Guide
1.04
ETRX1 and ETRX2
©2008 Telegesis (UK) Ltd
ETRXn User Guide (Rev 1.04)
0123
Same as 0122, but if applicable the timer will restart.
0200
Show the node‟s connection status on I/O10. LED on (pin driven low) = no connection. Blinking
fast = Auto-searching for PAN. Blinking slow = connected to PAN. The accompanying counter
register defines the update interval. Note: I/O10 must be defined to be an output in S0D/S0E.
0201
Show AT Command line‟s error status on I/O11. LED off = no error. LED blinking = error. Reset by
successful operation producing an „OK‟ prompt. The accompanying counter register defines the
update interval. Note: I/O11 must be defined to be an output in S0D/S0E.
2000
When triggered the number of times listed in the accompanying counter a message is sent to the
sink containing a transmission counter and the reading of the analogue and digital inputs. Note:
Can only be triggered by setting S15 or S16 to 400x.
2001
When enabling this action the command line is disabled and as soon as a number of bytes in
excess of the number specified in the accompanying timer/counter register is received on the serial
port, a SCAST
containing these characters is sent to the network‟s sink. If no sink is known a sink
is searched instead. After 3 unsuccessful transmissions the sink is assumed unavailable and a
new sink is searched.
Note:
This event is triggered by receiving a character on the serial port.
Prompt on the sink: SCAST:<EUI64>=<data>
where <EUI64> is the sender
‟s ID and <data> is the data payload
3000
The contents of S2B is sent to the local command line followed by carriage return. (Please note
that when writing to S2B
the “AT” suffix needs to be omitted). Please note that all commands
being entered to the AT command interface at the instance this action gets triggered get
interrupted and discarded. If applicable the timer will stop.
3001
Same as function 3001 but the timer will restart.
3002
The contents of S2C is sent to the local command line followed by carriage return. (Please note
that when writing to S2C the “AT” suffix needs to be omitted). Please note that all commands being
entered to the AT command interface at the instance this action gets triggered get interrupted and
discarded. If applicable the timer will stop.
3003
Same as function 3002 but the timer will restart.
400x
Start timer x. If applicable the timer will stop.
401x
Start timer x. If applicable the timer will restart.
402x
Toggle timer x. If applicable the timer will stop.