nstallation Guide
Page 24
System Configuration and Installation
Step 1:
Connect a shielded, straight-through 9-to-9 serial cable from the serial port of the computer
to the
AUX
port of the
Eye
III+
transmitter
.
Step 2:
Turn on the
Eye
III+
transmitter
.
A blue light at the front panel will flash continuously if
it is successfully turned on.
Step 3:
Install the
Eye
III+
‘s Reception Software (WRS3-AD)
from the CD-ROM to the
computer.
Step 4:
After installation, from Start menu, select
Program Files
Eye
III+
Transmitter
Configuration
to run the Configuration
program. Then, the Configuration
program should appear as shown below:
Step 5:
Click on the
General
page. In the
Connection
group with
Device
menu,
choose the suitable
serial port (COM1 or COM 2 or so on) for current connection to the transmitter. At the same
time, enter the administrator password at the
Admin Pwd
field (The default administrator
password is
“000000”
).
Step 6:
Click the
Connect
button. Please wait while it is connecting to the transmission unit. If
Transmission unit not found!
message is displayed, make sure that your cable connection
between the transmitter and your PC is well connected. And you can close the configuration
program and redo step 4.
Step 7:
A
Completed(
[baud rate]
)
message box will be displayed. The transmitter default
information will be displayed at each field (Figure 3.2).