May
2015
WorkHorse H-ADCP Operation Manual
Page 24
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Figure 13.
300 kHz NB H-ADCP Mounting Holes
The two M12 tapped holes on the top edge of the mounting plate are used to help handle the
system during production of the H-ADCP.
Do not use these holes to mount the H-ADCP or connect any other metal structures to the
H-ADCP.
and destruction of the H-ADCP.
Poor Mount
H-ADCP mount is using the two M5 tapped holes to connect to a
metal structure.
Good Mount
H-ADCP mount uses the three user mounting holes with isolation
bushings. Does not use the two M5 tapped holes.
Photos by Drs. P.E. Meijer / CEO Aqua Vision