May
2015
WorkHorse H-ADCP Operation Manual
Page 88
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
•
Your H-ADCP fails any of the following PA tests provided the items indicated by {} have been
checked:
Recorder Tests
:
Any recorder tests fails {provided that the PCMCIA card(s) have been checked for proper
installation, operation and they are DOS formatted; we STRONGLY recommend checking
PCMCIA cards in a computer before replacing the boards}
System Tests
:
Transmit {if the H-ADCP fails when it is in water and air bubbles have been rubbed from
the faces}
Sensor Tests
:
H/W Operation {if the H-ADCP fails when it is NOT sitting/resting on its side, or located
near a large magnetic field like a motor in a boat}
The spare boards kit will not correct any of the following failures:
•
A damaged beam or its urethane surface
•
Damage to the transducer beam connections below the copper shield
•
If it passes all PA tests and yet the data is all marked as bad
•
Fails the following PA test:
System Tests
:
Wide Bandwidth {bandwidth tests may fail due to external interference}
Narrow Bandwidth {bandwidth tests may fail due to external interference}
RSSI Filter
Transmit
Table 7:
Pre-deployment Test (PA) Possible Cause of Failures
PA Test Name
Possible Cause of Failure
Pre-Deployment Tests CPU Tests:
RTC
RAM
ROM
CPU board failed
Recorder Tests:
PC Card #0
Card Detect
Communication
DOS Structure
Sector Test (short)
PC Card #1
Card Detect
Communication
DOS Structure
Sector Test (short)
PC card not plugged in
PC card failed
DSP board failed
DSP Tests:
Timing RAM
Demod RAM
Demod REG
FIFOs
DSP board failed
System Tests:
XILINX Interrupts
DSP or CPU board failed
Receive Loop-Back
DSP or CPU board failed
Wide Bandwidth
Not in water
External interference
DSP or Receiver board failed
Narrow Bandwidth
RSSI Filter
Transmit
Not in water or PIO board failed
Sensor Tests:
H/W Operation
PIO board failed
Receiver board failed
Pressure sensor failed
H-ADCP laying on its’ side