WorkHorse H-ADCP Operation Manual
May
2015
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 119
Command Summary
gives a summary of the H-ADCP input commands, their format, and a brief description of the
parameters they control. Table 13
lists the factory default command settings.
This table shows all commands including optional feature upgrades and expert commands. To
see the expert commands, you must first send the command EXPERTON. Some commands may
not be available for your H-ADCP.
When newer firmware versions are released, some commands may be modified or added. Read
the README file on the upgrade disk or check TRDI’s web site for the latest changes.
Table 12:
H-ADCP Input Command Summary
Command
Description
?
Shows command menu (deploy or system)
<BREAK> End
Interrupts or wakes up H-ADCP and loads last settings used
EXPERTON
Turns expert mode on. All commands will be listed
EXPERTOFF
Turns expert mode off.
OL
List features/special firmware upgrades that are installed
AC
Output calibration data
AD
Display factory calibration
AF
Field calibrate compass to remove hard iron error
AR
Return to factory calibration
AX
Examine compass performance
AZ
Zero pressure sensor
BA
nnn
Evaluation amplitude minimum (1 to 255 counts)
BB
nnnn
High Bandwidth Maximum Depth (dm)
BC
nnn
Correlation Magnitude minimum (0 to 255 counts)
BE
nnnn
Error velocity maximum (0 to 9999 mm/s)
BF
nnnn
Depth guess (1 to 65535 dm, 0 = automatic)
BGss,dd,nnnnn
BHccc,sss,lll,mmm
BI
nnn
Gain switch depth (0 to 999 meters)
BK
n
Water-mass Layer Mode (0-Off, 1-On, 2-Lost, 3-No BT)
BL
mmm,nnnn,ffff
Water mass layer parameters: Min Size (dm), Near (dm), Far (dm)
BM
n
Bottom track mode (5 = Default, 4 = Default minus Coherent)
BP
nnn
Bottom Track Pings per Ensemble
BR
n
Resolution (0 = 4%, 1 = 2%, 2 = 1%)
BS
Clear distance traveled
BX
nnnn
Maximum Tracking Depth (40 to 65535 dm)
BZ
nnn
Coherent ambiguity velocity (cm/s radial)
CB
nnn
Serial port control (baud rate/parity/stop bits)
CF
nnnn
Flow control
CK
Keep parameters as user defaults
CLn
Sleep between Pings (0 = No, 1 = Yes)
CM
n
Not used.
CN
n
Save NVRAM to recorder (0 = On, 1 = Off)
CP
n
Polled mode (0 = Off, 1 = On)
CQ
nnn
Transmit power (0 = Low, 1 to 255 = High)
CR
n
Retrieve parameters (0 = User, 1 = Factory)
CS or
Tab
Start pinging
CY
n
Clear error status word (0 = Clear, 1 = Display)
CZ
Power down H-ADCP
DB
x,y,z
RS-485 port control
DS
Load speed of sound with SVSS sample
DWx
Current ID on RS-485 bus (0 to 31)
DX