Table 12:
H-ADCP Input Command Summary
Command
Description
WA
nnn
False target threshold maximum (0 to 255 counts)
WB
n
Mode 1 Bandwidth Control (0 = Wide, 1 = Narrow)
WC
nnn
Low correlation threshold (0 to 255 counts)
WD
nnn
nnn
nnn
Data Out (Vel;Cor;Amp PG;St;P0 P1;P2;P3)
WE
nnnn
Error correlation threshold (0 to 5000 mm/s)
WF
nnnn
Blank after transmit (0 to 9999 cm)
WI
n
Clip data past bottom (0 = Off, 1 = On)
WJ
n
Receiver gain select (0 = Low, 1 = High)
WL
sss,eee
Water reference layer
W
Nnnn
Number of depth cells (1 to 128)
WP
nnnn
Pings per ensemble (0 to 16384)
WQ
n
Sample ambient sound (0 = Off, 1 = On)
WS
nnnn
[min, max]
Depth cell size, 20 to 800 (300kHz), 10 to 800 (600kHz)
WT
nnnn
Transmit length (0 to 3200 cm)
WU
n
Ping weight (0 = Box, 1 = Triangle)
WV
nnn
Ambiguity velocity (002 to 480 cm/s radial)
WW
nnn
Mode 1 Pings before Mode 4 Re-acquire
WY
n,nnn
WM 1: Bandwidth (0=WB, 1=NB), Amb. Vel.(cm/s)
Table 13:
H-ADCP Factory Defaults
Command
300 kHz
600 kHz
BA
30
30
BB
320
160
BC
220
220
BE
1000
1000
BF
0
0
BI
20
10
BK
0
0
BL
160,320,480
80,160,240
BM
5
5
BP
0
0
BR
1
1
BX
350
150
BZ
4
4
CB
411
411
CF
11110
11110
CL
1
1
CM
0
0
CN
1
1
CP
0
0
CQ
255
255
DB
611
611
DW
0
0
EA
+0
+0
EB
+0
+0
EC
1500
1500
ED
0
0
EH
0
0
EP
+0
+0
ER
+0
+0
ES
0
0
ET
+2500
+2500
EX
01110
01110