WorkHorse H-ADCP Operation Manual
May
2015
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 107
Table 8:
Water Profiling Specifications
Cell Size
1
Horizontal
Resolution
H-ADCP 300
300kHz nominal (LR mode
2
)
148m (187m)
H-ADCP 600
600kHz nominal (LR mode
2
)
60m (75m)
H-ADCP-N 300
300kHz nominal (LR mode
2
)
178m (221m)
Range (m)
Std Dev (cm/s)
Range (m)
Std Dev (cm/s)
Range (m)
Std Dev (cm/s)
Nominal
Long
Nominal
Long
Nominal
Long
Nominal
Long
Nominal
Long
Nominal
Long
0.5m
41
54
11.03
23.14
1.0m
99
134
10.97
23.01
45
59
5.66
11.87
126
164
13.55
28.44
2.0m
108
145
5.62
11.74
49
64
2.89
6.05
136
176
6.94
14.51
4.0m
120
158
2.87
6.02
54
70
1.36
2.83
149
190
3.55
7.44
8.0m
134
173
1.36
2.89
60
75
0.6
1.22
163
205
1.73
3.68
16.0m
148
187
0.6
1.32
178
221
0.77
1.65
Aspect
Ratio
Limitation
12/1 (range/tonal depth)
12/1 (range/tonal depth)
19/1 (range/tonal depth)
1.
User’s choice of cell size is not limited to the typical values specified.
2.
Range, which depends on cell size, is specified here for narrow bandwidth mode at 5°C,
typical ocean backscatter, and nominal 48VDC input power. Default configuration is LR
mode (
Table 9:
Specifications
Profile Parameter
s
H-ADCP 300
H-ADCP 600
H-ADCP-N 300
Velocity accuracy
±
0.5%
±
5mm/sec
±
0.25%
±
2.5mm/sec
±
0.5%
±
5mm/sec
Velocity resolution
0.1cm/s
0.1cm/s
0.1cm/s
Velocity range
±
5m/s (default),
±
20m/s
(max)
±
5m/s (default),
±
20m/s
(max)
±
5m/s (default),
±
20m/s
(max)
No. of depth cells
1
–
128
1
–
128
1
–
128
Error velocity data
rejection
Yes; required on a single-ping basis to screen errors from passing vessels
Transducer and
Hardware
H-ADCP 300
H-ADCP 600
H-ADCP-N 300
Beam width
2.1
°
1.3
°
1.1
°
Beam angle
25
°
25
°
20
°
System Weight
H-ADCP 300
H-ADCP 600
H-ADCP-N 300
In Air
16kg
14kg
72.1kg
In Water
10kg
8.6kg
56.2kg
Environmental
H-ADCP 300
H-ADCP 600
H-ADCP-N 300
Standard depth rating
200 meters
Operating temperature
-5
°
to 45
°
C
Storage temperature
-30° to 60°C