May
2015
WorkHorse H-ADCP Operation Manual
Page 186
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Table 31:
Waves Flow Control
Command
Description
HFxxx22
Use the same settings as the CF command (default)
HFxxx1x
Enable Serial Output – Sends the currents and waves data ensemble out the RS-232/422 serial interface.
HFxxx0x
Disable Serial Output – No waves ensemble data are sent out the RS-232/422 interface.
HFxxxx1
Enable Data Recorder – Records waves data ensembles on the recorder (if installed).
HFxxxx0
Disable Data Recorder – No waves data ensembles are recorded on the recorder.
The default HF22222 will be displayed as HF00000 when a “HF?” command is run.
HP – Waves Pings per Wave Record
Purpose
Set the number of pings per wave record.
Format
HPn
Range
n = 0 to 8400
Default
HP0
Recommended Setting.
Set using
WavesMon
.
Description
The command sets the number of pings collected per wave record (or burst). With this
value set to zero, Waves data collection is disabled.
HR – Time Between Wave Records
Purpose
Set the maximum interval between the start of each wave record.
Format
HR hh:mm:ss.xx
hh – hours
mm – minutes
ss – seconds
xx – hundredths of seconds
Range
00:00:00.00 – 23:59:59.99
Default
HR01:00:00.00
Recommended Setting.
Set using
WavesMon
.
Description
This command sets the maximum interval between the start of consecutive wave records.
If the number of pings per record * the time between pings is greater than the time be-
tween wave records, then the previous wave record will complete before starting the next
one.