WorkHorse H-ADCP Operation Manual
May
2015
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 23
Attaching the H-ADCP to a Structure
Attach the H-ADCP to a rigid structure, solid wall, pier, or pile. The mounting structure must be firm, sta-
ble, without settlement or displacement over time.
Double-check all of the connections, seals, and bolts. Connect the I/O cable and make sure that the strain
relief is attached to the cable. Make sure that the I/O cable is routed so that it is not subject to becoming
entangled or snagged.
Bolt the H-ADCP to the structure using isolating bushings when mounting the H-ADCP to a metal struc-
ture.
Your H-ADCP transducer housing and mounting plate is made of aluminum that is protected by
Do not connect other metal to the H-ADCP
.
Other metals may cause corrosion damage
.
Use isolating bushings when mounting the H-ADCP to a metal structure
. Keep this in mind
when fabricating a fixture, which materials to use, or deciding how to place it at the installation
site.
Figure 12.
Optional Mounting Kit (P/N 757K6085-00)