42
Piranha4 8K Camera Color User's Manual
03-032-20156-02
Teledyne DALSA
GenICam parameters to set:
I / O Controls > Trigger Mode > On
Sensor Control > Exposure Mode > Trigger Width
Warning!
When ru nning external line rate and external exp osu re tim e, the line rate m u st not exceed 1 /
(exp osu re tim e + 1,500 ns). Und er these cond itions the exp osu re tim e w ill becom e ind eterm inate and
resu lt in im age artefacts. This is not the case w hen ru nning internal exp osu re control .
3. External Line Rate, Programmable Exposure Time
In this m od e, the line rate is set externally w ith the falling ed ge of EXSYN C generating the rising ed ge of
a p rogram m able exp osu re tim e.
GenICam parameters to set:
I / O Controls > Trigger Mode > On
Sensor Control > Exposure Mode > Ti med