4.1.4. Button Operation
Note: Continuous display of both Methane and CO is a configurable option, as
shown in
Action
Button
Note
Invert Display
Press
Max
1
Press and Hold
Displays the Maximum readings since the mode
was selected.
To return to live readings, press and hold again or
wait 30 seconds.
Alarm
Acknowledging
Press and Hold
Available when monitor is in alarm.
Refer to
Range
Selection
2
Press
Toggle between "Methane" and "Methane & CO"
displays.
Lights
Press and Hold
1st press and hold - backlight ON
2nd press and hold - flashlight ON
3rd press and hold - backlight/flashlight OFF
Backlight / flashlight automatically switch OFF
after two minutes.
Pump
ON/OFF
Press
Clear Flow Fault
Press
Available only when monitor has a flow fault