Falcon4 86M Cameras
Contents
55
Advanced Processing Control Category
The camera‘s Advanced Processing controls, as shown in CamExpert, group parameters used to
configure Defective Pixel Detection, Flat Field calibration.
Advanced Processing Control Feature Descriptions
The following table describes these parameters along with their view attribute.
Display Name
Feature & Values
Description
Standard
& View
Correction Mode
flatfieldCorrectionMode
Sets the mode for flat field correction.(RW)
DFNC
Beginner
Off
Off
Flat field correction is disabled.
Active
ActiveAll
Flat field correction is enabled. FPN and
PRNU correction is active.
Active, FPN Only
ActiveFPNOnly
FPN correction is active.
Active, PRNU
Only
ActivePRNUOnly
PRNU correction is active.
Calibration
Calibration
The camera is configured to calibration
mode (Only available when TriggerMode =
Off, flatfieldCorrectionCurrentActiveSet is
not FactoryFlatfield,).
The device may automatically adjust some
features in the camera when calibration
mode is enabled. The features that are
automatically adjusted are device specific.
The device will not restore these features
when the flat field correction mode is
changed from calibration mode to another
mode.
It is not available for FactoryFlatfield1
[Global Shutter Factory Flat Field]
FactoryFlatfield2 [Rolling Shutter Factory
Flat Field].
It is not available for external mode, and it
is not available for AOI smaller than 2048
horizontal.
Current Active
Set
flatfieldCorrectionCurrentActiveSet
Specifies the current set of flat field
coefficients to use. This feature cannot be
changed while the camera is in flat field
calibration mode. Read-Write (Read-Only
when in Calibration Mode).
DFNC
Beginner
Global Shutter
Factory Flat Field
FactoryFlatfield1
Factory calibrated flat field for Global
Shutter Mode
Rolling Shutter
Factory Flat Field
FactoryFlatfield2
Factory calibrated flat field for Rolling
Shutter Mode.
User Flat Field 1
to
User Flat Field 3
UserFlatfield1
to
UserFlatfield3
User Flat Field 1 to User Flat Field 3: User
configurable flat field sets
Pixel X
Coordinate
flatfieldCorrectionPixelXCoordinate
Specifies the X coordinate of the flat field
pixel coefficient to access. (RW) To
configure, set Correction Mode to
Calibration. Range: 1 to
SensorWidth
Beginner