2 – System Overview
DPN 402196 Issue 4.1
© Teledyne TSS
2- 5
against this type of damage, always take the following precautions:
❐
Never try to use unauthorised software with the SDC.
❐
Never power-on or reset the SDC with a USB drive connected unless you
need to reinstall all the SDC10 software (see
).
❐
Use an external PC running up-to-date anti-virus software to check digital
media before you use them with the SDC. Use only virus-free digital media
with the SDC. You may install appropriate and approved virus protection soft-
ware on the SDC if you prefer. To maintain full effectiveness you must keep
this type of protection up to date.
❐
Do not use any digital media with the SDC if you are unsure whether it is free
from viruses.
❐
Do not power-on the SDC if you suspect a virus has infected it.
Teledyne TSS takes every possible precaution to prevent virus infection before
shipment. If you suspect your SDC has become virus infected, contact Teledyne
TSS for advice and then arrange to return the SDC to Teledyne TSS for repair.
2.3 Sub-sea Components
The sub-sea installation comprises the following component parts:
❐
A Sub-sea Electronics Pod (SEP).
❐
A Sub-sea Power Supply Unit (PSU).
❐
A coil array with three Teledyne TSS search-coils. See
section 3.1.3.3 "Coil Assembly and
for instructions to install the coils.
❐
Frame components to mount the coils onto the ROV.
❐
A sub-sea altimeter.
❐
Cables to interconnect the sub-sea components of the 440 System and to connect them to the
electrical distribution system of the ROV.
2.3.1 Power Supply Unit
The PSU accepts a single phase AC electrical supply nominally at 110V AC at 45 to 65Hz. A switched-
mode circuit inside the PSU generates the conditioned DC supplies required by the SEP, with all DC
supplies passing through a
-filter network to prevent noise and interference from reaching the SEP.
See
section 8.1.3 "Sub-sea Power Supply Pod" on page 8-3
for full details of the PSU power
requirement. There is a cartridge fuse inside the PSU to protect the System from overload conditions.
The PSU has a port for connection to the ROV electrical distribution system and umbilical. This
connection uses a Power and Communications cable supplied with the System that has a multiway
connector that mates to the PSU and open tails for connection to the ROV.
Connection between the SEP and the PSU is through a single cable that has a multiway connector at
each end.
Summary of Contents for 440
Page 12: ...List of Figures x Teledyne TSS DPN 402196 Issue 4 1 ...
Page 18: ...Glossary xvi Teledyne TSS DPN 402196 Issue 4 1 ...
Page 24: ...1 Introduction 1 6 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 32: ...2 System Overview 2 8 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 66: ...4 Electrical Installation 4 20 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 88: ...5 Operating Software 5 22 Teledyne TSS DPN 402196 Issue 4 1 Figure 5 10 Altimeter Test ...
Page 144: ...6 Operating Procedure 6 40 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 154: ...7 Operational Considerations 7 10 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 164: ...8 System Specifications 8 10 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 203: ...10 System Drawings DPN 402196 Issue 4 1 Teledyne TSS 10 17 Figure 10 15 SDC10 Dimensions ...
Page 230: ...A Operating Theory A 12 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 242: ...B Options B 12 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 244: ...C Altimeter C 2 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 246: ...D Reference D 2 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 248: ...D Reference D 4 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 250: ...D Reference D 6 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 252: ...D Reference D 8 Teledyne TSS DPN 402196 Issue 4 1 ...
Page 254: ...D Reference D 10 Teledyne TSS DPN 402196 Issue 4 1 ...