4220 Flow Meter
Section 5 Options and Accessories
5-25
the flow meter. You can use the YSI 600 as deep as 200 feet below
the surface, or in as little as a few inches of water. The fast sensor
response of the YSI 600 makes it ideal for vertical profiling. Its
small size means it can fit inside two-inch diameter monitoring
wells.
A
Rapid Pulse Dissolved Oxygen Sensor
eliminates the need
for stirring, providing accurate results without an expensive and
bulky stirrer. Because no stirring is required, no supplemental
power supply or battery is needed, and sensor drift caused by
passive fouling is minimized.
The YSI 600 communicates with any 4200 Series flow meter
equipped with suitable hardware and software. Earlier model
4200 flow meters can be factory-modified to work with the YSI
Sonde. Data can be exported through Flowlink for further pro-
cessing.
The YSI 600 is available with a 25 foot cable to connect to the
flow meter. The cables are waterproof at the sonde and can be
used in lab or field.
Information about programming the flow meter to use the YSI
600 is found in Section 2 of this manual. Information about the
YSI 600 Sonde is found in the YSI manual.
Table 5-5 YSI 600 Probe Specifications
Complete Unit
Medium
Fresh, Sea, or Polluted Water
Temperature
–5° to +45° C
Storage Temp
–40° to +60°C
Depth
0 to 200 Feet (0 to 61 meters)
Diameter
1.6 Inches (4.06 cm)
Length
14 Inches (35.6 cm)
Weight
4.9 Pounds (2.22 kg)
Materials PVC,
Stainless
Steel
Computer Interface
RS-232C, SDI-12
Power
12VDC, Externally supplied
System Requirements
Connects to
modified
9-pin Rain Gauge Termi-
nal on any 4200 Series Flow Meter. Operation of
Rain Gauge with YSI 600 is still possible with a
special Y-connect cable. Modification of older
4200 Series Flow Meters is possible with
changes in connectors and boards. Consult fac-
tory.
Sensor Specifications
Temperature
Sensor Type
Thermistor
Range
–5° to +45° C
Summary of Contents for 4220
Page 2: ......
Page 4: ......
Page 8: ...4220 Flow Meter Safety ...
Page 14: ...vi ...
Page 19: ...4220 Flow Meter Section 1 Introduction 1 5 Figure 1 2 4220 Controls and Indicators ...
Page 28: ...4220 Flow Meter Section 1 Introduction 1 14 ...
Page 94: ...4220 Flow Meter Section 3 Installation 3 12 ...
Page 156: ...4220 Flow Meter Appendix A Replacement Parts A 2 ...
Page 157: ...4220 Flow Meter Appendix A Replacement Parts A 3 ...
Page 160: ...4220 Flow Meter Appendix A Replacement Parts A 6 ...
Page 164: ...4220 Flow Meter Appendix B Accessories List B 4 ...
Page 172: ...4220 Flow Meter Appendix C Programming Worksheets C 8 ...
Page 182: ...4220 Flow Meter Appendix D General Safety Procedures D 10 ...
Page 194: ......
Page 196: ...Warranty ...
Page 198: ......