TCM260904
Rev
0.1
TCM260904
Page 20 of 31
O
THER
T
RANSMITTER
F
UNCTIONS
Item Title
Options
Description
A Power-On
1.
Mushroom or key
2.
Mushroom
3.
Key
4.
Any pushbutton
5.
Start pushbutton
6.
E.U. ( standard)
7.
E.U. ( simple)
“Power-ON”:
It means that the stop relay of receiver is
energized.
“Mushroom or Key Power-On mode”:
This mode
means that the receiver will be in the Power-On mode if
one of the “Mushroom Power-On” or “Key Power-On” is
executed.
“Mushroom Power-On mode”:
The receiver will be in
the Power-On mode when the mushroom is pulled out,
when the key is in the “on” position.
“Key Switch Power-On mode”:
The receiver will be in
the “Power-On” mode when the rotary key switch is
turned from “off” to “on” position, when the mushroom is
in the “off” position (i.e. mushroom is pulled up).
“Any pushbutton Power-On mode”:
The receiver will
be in the “Power-On” mode when any pushbutton on the
transmitter is pressed, when mushroom is at “off” (i.e.
pulled out) position and key is at “on” position.
“Start pushbutton Power-On mode”:
The receiver will
be “Power-On” once Start pushbuttons is pressed, when
mushroom is at “off” position and key is at “on” position.
“E.U. (standard) Power-On mode”:
The receiver will be
in the “Power-On” mode when the rotary key switch is
rotated to the “Start” position, when the mushroom is at
“off” position. In case the receiver is Powered off due to
the mushroom being pressed or “Auto Off”, one must turn
the rotary key switch to “off” position, then turn to “on”
position, and to “Start” position to turn on the power. This
mode is continuously transmitting and will automatically
turn off after 3 minutes of non-operation.
“E.U. (simple) Power-On mode”:
The receiver will be in
the “Power-On” mode once the rotary key switch is
rotated to “Start” position, when mushroom is at “off”
position and key is at “on” position. The only difference
from “E.U. (standard)” is that in this mode, one doesn’t
need to turn the rotary key switch to “off” position and
then to “on” position to re-start.
B Auto
Off 1.
No
2.
Yes
“Auto Off”:
The transmitter will turn off the power
supply automatically if there is no operation for a certain
time. Whether to transmit an EMS signal to “Power-Off”
the receiver before the transmitter turns off can be set by
this function.
“Power-off”
means that the Stop Relay of receiver is de-
energized. Hence, one must perform the “Power-On”
procedure to turn on the receiver power.
C Transmit 1.
Non-continuous
2.
Continuous
“Non-continuous transmitting mode”:
After “Power-
On”, the transmitter will transmit a signal only when the
pushbutton is pressed. This mode can save the transmitter
battery power.
“Continuous transmitting mode”:
The transmitter will
continuously transmit a signal while Powered on.